Connect/Gateway panel guide: Honeywell GALAXY

Equipment required

  • A Nimbus Connect or Fixed Gateway device

  • 3 core screened data cable

Panel configuration

  1. Enter engineer mode

  2. Select menu 56

  3. Select Internal RS232 communications port:
    1. Mode = Direct
    2. Format = SIA – Level 4
      • Select the event types that you want to output and for which groups PA/Duress
        • Intruder 
        • 24 Hours 
        • Security
        • Custom Zone
        • Fire
        • Set Fault
        • Omit
        • Tamper
        • Setting
        • Reset/Cancel
        • Modules/Comms
        • Elec Status
        • Menu Access
        • Trouble
        • Log Zone
        • Max Tag
        • Zone Restoral
        • RF Supervision
        • Fault
    3. Set an account number (6 digits max)
    4. Communications settings:
      • Baud = 9600
      • Data = 8
      • Parity = None
      • Stop = 1

If you do not configure the panel to SIA upto level 4, then the panel will not output events during walk tests.


Wiring

Using 3 core screened data cable wire to the Nimbus RS232 as follows.

Galaxy PCB Nimbus RS232
GND Ground
Tx Rx
Rx Tx