nimbusGo panel guide: Honeywell Intruder Galaxy Panel

Equipment required

From Nimbus

From the panel manufacturer/3rd party

  • n/a


Panel configuration

The communications port should be configured as follows:

Enter engineer mode

Select menu 56

Select Internal RS232 communications port:

    Mode = Direct

    Format = SIA – Level 3

          Select the event types that you want to output and for which groups

          PA/Duress

          Intruder 

          24Hours 

          Security

          Custom Zone

          Fire

          Set Fault

          Omit

          Tamper

          Setting

          Reset/Cancel

          Modules/Comms

          Elec Status

          Menu Access

          Trouble

          Log Zone

          Max Tag

          Zone Restoral

          RF Supervision

          Fault

Set an account number (6 digits max)

Communications settings:

        Baud = 9600

        Data = 8

        Parity = None

        Stop = 1

When performing a walk test the Galaxy panel will not output to Nimbus

To resolve this issue you can configure SIA level 4 instead which allows remote control, when a walk test is started and SIA level 4 is configured. The gateway will then attempt to poll all zones for state changes.


Panel connections

Connect nimbusGo to the RS232 card via the 2m Adapter Lead and the Multi Panel (Tx, Rx, Gnd) Panel Adapter

You will now see the panel LED on nimbusGo turn green, and "good" panel comms will be indicated in Nimbus Engineer.